NCB Polyaxial Large Fragment Plates

The NCB (Non-Contact Bridging) Large Fragment System is a line of polyaxial locking plates for the treatment of femur, tibia and humerus shaft fractures. It consists of a Curved Femur Shaft plate and a Straight Narrow Shaft Plate. The NCB Curved Femur Shaft Plate is also included in the NCB Periprosthetic Femur Polyaxial Locking Plate System.

Symmetric Design

There is only one plate for left and right long bones due to symmetric design. The NCB Straight Narrow Shaft Plate can either be used for the tibia or humerus. Whereas the NCB Curved Femur Shaft Plate is specifically designed for the femur.

K-Wire Holes

Two k-wire holes at each end of the plate allow easier preliminary plate fixation.

Compression Slots

Two compression slots allow 1mm of compression each.

Polyaxiality

The NCB Plate Technology allows polyaxial screw placement (30° cone) with screw locking achieved through the use of locking caps that are threaded into the plate holes. The locking construct improves stability especially in poor bone quality.

Non-Contact Bridging

In the locked mode the NCB Large Fragment Plate acts as an internal fixator without contact between the plate and the bone surface, which may reduce the risk of impairment to the periosteal blood supply. This Non-Contact Bridging concept can also be controlled through the use of 1, 2 or 3mm spacers, which are threaded into the plate holes prior to plate insertion.

Broad Screw Options

Three different NCB Screw types are offered with the NCB Large Fragment Plates, to allow both bicortical and unicortical fixation.

Cable Fixation Options

The products from the Zimmer ® Cable-Ready ® Cable Grip System are compatible with the NCB Large Fragment System.

Flexibility

The NCB Straight Narrow Shaft Plate and the NCB Curved Femur Shaft Plate can be implanted using the following existing instrument sets.

NCB Curved Femur Shaft Plate

Symmetric Design

There is only one plate for left and right femurs due to symmetric design.

Compression Slots

Two compression slots allow 1mm of compression each.

Articulated Tension Device Holes

One hole at each end of the plate allows for connection of the Articulated Tension Device to achieve additional compression, if needed.


All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.  
This material is intended for health care professionals. Distribution to any other recipient is prohibited.
For product information, including indications, contraindications, warnings, precautions, potential adverse effects and patient counseling information, see the package insert and information on this website. To obtain a copy of the current Instructions for Use (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support.