N-Force Fixation System®

1000x1000_insetimage_Trauma_Zimmer NForce

An augmented fixation system, integrating fenestrated screws and a Bone Substitute Material (BSM) into a single construct to provide improved metaphyseal void fill and increase structural support of the implant.1

The N-Force Fixation System is comprised of fenestrated screws, washers and the Bone Substitute Material (BSM) N-Force Blue. N-Force Blue is injected directly into the fenestrated screw with the use of a sheath assembly to help minimize BSM leakage into the soft tissues.

Not only do the N-Force screws provide fixation, they are also a delivery system for filling bone voids. Because defects are filled after reduction, the screw can be placed precisely in the desired location. The system is designed to create a more complete fill of the bone void and increase structural support of the implant.

N-Force Blue is the only FDA cleared BSM that is validated for use with the N-Force Fixation System. Zimmer Biomet recommends that N-Force Blue be used with the N-Force Fixation System.

 

Specific System Details:

  • 4.0 mm and 7.3 mm N-Force Fixation System kits currently available
  • 4.0 mm screws available in fenestrated, fully-cannulated design as well as fenestrated, partially-cannulated design for use when the screw tip may penetrate the opposite cortex
  • 4.0 mm screws are sterile packed with a sheath assembly in order to facilitate the injection of N-Force Blue
  • 7.3 mm screws available in fenestrated, fully-cannulated design as well as non-fenestrated, fully-cannulated design
  • 7.3 mm screws are sterile packed with a sheath assembly and washer for surgical efficiency and to facilitate the injection of N-Force Blue.
  1. Internal report, Mart-Test, Inc.: 350% increase in bench-top screw pull-out strength with BSM versus no BSM; funded by InnoVision, August 2009.  The material used in this testing is chemically identical to the calcium phosphate found in N-Force Blue. 

Legal Manufacturer:

Zimmer, Inc.
1800 West Center Street
Warsaw, Indiana 46580 USA


All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.  
This material is intended for health care professionals. Distribution to any other recipient is prohibited.
For product information, including indications, contraindications, warnings, precautions, potential adverse effects and patient counseling information, see the package insert and information on this website. To obtain a copy of the current Instructions for Use (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support.