JuggerKnot® Soft Anchor System

All-Suture Technology

Zimmer Biomet revolutionized soft tissue fixation in Sports Medicine with the introduction of the JuggerKnot anchor platform in 2009 with the 1.4 mm JuggerKnot, and we haven’t looked back. This award winning 100% suture based anchor system has quickly evolved into a family of anchors that offers the widest range of options for a multitude of different procedures.

  • Clinical Results: One study, performed with the 1.4 mm anchor, demonstrated clinically improved patient outcomes and fibrous tissue complete bony healing or combined fibro-osseous healing in the anchor tunnel1
  • Versatile: Gain access to the most robust soft anchor system on the market, which includes seven different size offerings and size specific instrumentation.
  • Strong: Strength is equal to or greater than some anchors two or three times larger2 and high pullout strength ranging from 20-120 lbs., depending on size of anchor3,4

JuggerKnot Soft Anchor-1.0 mm Mini

insetimage_SportsMed_JuggerKnot1.0_01
  • Most commonly utilized for soft tissue to bone fixation in the hand
  • Designed with a #1 polyester sleeve, loaded with either a #2-0 or #3-0 MaxBraid™ suture, and loaded with two T-28 tapered needles
  • Sleeve protector eliminates the need for a drill guide
  • Currently the smallest all-suture anchor on the market
  • 26 lbs. anchor pullout strength with #2-0 and 20 lbs anchor pullout strength with #3-0 suture4
  1. Agrawal, V, MD; Pietrzak, WS, Ph.D. Triple labrum tears repaired with JuggerKnot™ soft anchor: Technique and results. Int J of Shoulder Surg 2015;9:81-9.
  2. Barber FA, MD, Herbert MA, Ph.D. “Cyclic Loading Biomechanical Analysis of the Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2013 Update.” Arthroscopy, 29(5), p832-844, April 2013
  3. Barber FA, MD, Herbert MA, Ph.D, Hapa O., MD, Rapley JA, MD, Barber CA, Bynum JA, MD, Hrnack SC, MD. “Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update.” Arthroscopy, 27(7), p895-905, July 2011
  4. Data on file at Biomet Sports Medicine. Test Reports, AT47B, AT47D, BSM4, BSM03. Bench test results are not necessarily indicative of clinical results.

 

Legal Manufacturer:

Biomet Orthopedics
56 East Bell Drive
P.O. Box 587
Warsaw, Indiana 46581 USA


All content herein is protected by copyright, trademarks and other intellectual property rights, as applicable, owned by or licensed to Zimmer Biomet or its affiliates unless otherwise indicated, and must not be redistributed, duplicated or disclosed, in whole or in part, without the express written consent of Zimmer Biomet.  
This material is intended for health care professionals. Distribution to any other recipient is prohibited.
For product information, including indications, contraindications, warnings, precautions, potential adverse effects and patient counseling information, see the package insert and information on this website. To obtain a copy of the current Instructions for Use (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support.